Servicing milking machines
Now is an ideal time to service your milking machine before spring.
Best practice industry guideline (from both CellCheck and IMQCS) is to test and service machines every six months as keeping your machine in good condition will minimise SCC, TBC and Thermoduric problems. GII recommends that suppliers use IMQCS certified technicians to service and test their machines.
Milking machine rubberware and silicone tubes become worn and perished over time – which allows bacteria to build up leading to high TBC and Thermoduric counts. Worn rubberware may leach unwanted chemicals into raw milk.
The guidelines for changing rubberware in milking machines:
- Milk Liners – as a minimum change every 2,000 milkings or every six months. High Thermoduric and TBC counts will result from bacteria building up in cracked, worn or damaged liners. Thus keeping these changed regularly will help control SCC, Thermoduric and TBC levels.
- Long milk tubes / elephant trunking, long and short pulse tubes – replace immediately if cracked, but as a minimum change every two years.
- Wash tubes, wash jetters and plugs – change at least every five years or earlier if necessary.
- Regulator filters should be checked and cleaned regularly, as dust may accumulate, especially where meal is being fed in the dairy.
- Silicone (red or clear) tubes - replace immediately if cracked, but as a minimum change every four years
Ensure you receive a full written test report as part of each service. This allows you to review how the milking machine is performing between years and can be passed on to farm advisors investigating SCC / mastitis issues on-farm. A milking machine service report must be available on farm for the Bord Bia audit. Should have any queries on servicing your milking machine, please do not hesitate to contact your GII Milk Quality Manager.
First Published 22 January 2016
Tagged with: Dairy