Checklist to investigate TBC results that are out of spec

684-X-384-Water-Quality.jpeg

Suppliers are tested at least twice per month for TBC. Additionally, every load arriving on site is sampled on arrival and tested for TBC. If a load is OOS – over 100,000 cfu/ml, then each supplier that was on that load that day have their individual samples tested for TBC.


TBC targets for the highest quality milk are <20,000 cfu/ml which indicates that wash routines and the environment are managed well.

Check these areas out if you have received an out of spec alert for TBC.  Take corrective action where you identify problems.

Total Bacteria counts (TBC) are measured in colony forming units – so if you get a text saying 5 – this means your result is actually 5,000 cfu/ml, and if you get one of 500, this means your result is actually 500,000 cfu/ml.

Thermoduric results are the actual numbers so a result there of 500 is actually 500 cfu/ml.


Results are communicated by either:

1.     An alert text is sent when the result is out of specification. This comes around midday - and highlights that there could be an issue. By alerting you in the middle of the day as soon as the result is available, this should give you time to check out possible problems before the next milking / next collection.

2.     A normal text that communicates all in specification results each evening.


The main areas to look at – detergent use, clean bulk tanks and clean milking machines, colling functioning of the bulk tank compressors and as always clean cows.


CHECKLIST

  • Compressor – are compressors fully gassed, working correctly, are the fans clean?

  • Bulk tank – is it turned on at all times when there is milk inside, and is it fully functioning?

  • Vacuum line - check weekly, wash out when build up found.

  • Claw pieces - check for biofilm, milk residue and any build up.

  • Cluster liners - when were they changed last? Check for any milk residue or biofilm and build up?
  • Other rubberware - when were they changed last? Check for biofilm and build up and milk residue on all the rubber pipes from short milk tubes to wash hoses.
  • Bulk tank - check outlet, agitator and lid and sides for build-up. Is it cooling fast enough? Are there any spray outlets / spray balls blocked? Is the lid / roof being fully cleaned.
  • Wash trough - are you using enough hot water?
  • Receiving jar/sanitary trap - check for cleanliness and build up.
  • Water– a couple of areas to check here.
  1. Firstly is the water hard? If so make sure you use a water softener to maximise detergent efficiency.
  2. Secondly is the water clean? Test for microbes and check.
  3. Thirdly are you using enough water volume to make sure the cleaning process is thorough.
  4. Fourthly and critically is the water temperature hot enough consistently to do correct washing. If you can’t get temperatures at 75 and then 55 at dumping, your hot water chemicals can’t do effective washing.
  • Auto washers - are they taking in enough product? Are the tubes kinked or crystallised? Does the auto washer change the product rotation over in the right sequence? There are different rates for hot and cold product mixing rate.
  • Caustic Detergent - is right amount being used? Is right rotation of products happening? What is the product strength?
  • Acid Detergent - is right amount being used? Is right rotation of products happening? You need to use at least two – three acid washes per week if using a manual powder regime, and daily acid washes for liquid detergent auto washer regimes. A weekly ACID DESCALE wash is no longer the recommended best practice.
  • Plate cooler – it’s really important to use a clean fresh filter for each milking. Then you should also use a filter at each washing to protect the plate cooler from build-up.

Very high TBC results e.g. over 1,000,000 cfu/ml tend to be mostly associated with cooling failures.


Checklist for these is slightly different as the bulk tank tends to be where we first check out.

  • Was the tank turned off at any stage? Once milk stays over 4C for any length of time, bacteria grow rapidly. Milk should not be sent in from a tank where it wasn’t cooled for several hours. Discuss this with your Milk Supply Manager before allowing the tanker to collect the milk. We do not advise just turning the tank back on.
  • Is the compressor adequate size – can it cool the milk? Do you have two compressors rather than one – this allows for a malfunction of one and allows the milk to say cooling.
  • Is the plate cooler working normally?
  • Have you installed a Bulk Tank Monitor – these can easily be retro fitted onto any bulk tank. They will alert you to the temperature of washing, cooling pattern and capacity.
  • Is your tank big enough to store and handle cooling for your volume of milk? You must be able to store 5 milkings at peak. There are finance options and grant funding available through TAMS grants (see this link: ie - Targeted Agriculture Modernisation Schemes (TAMS) (www.gov.ie)) and also through Fund Equip (see this link: Financial Tools | Tirlán (glanbiaireland.ie).

Further information can be found on our TBC Milk Quality Factsheet (part of our Milk Quality Factsheet series) HERE or you can contact your Milk Supply Manager to investigate further.

First Published 20 December 2022

Tagged with: Dairy

Processing