Bulk Tanks - Upgrade to save money

Tank_684x384.jpg

As cow numbers continue to increase, the need for both milk storage and cooling capacity is greater than ever.

Modern bulk tanks consistently outperform their predecessors when it comes to cooling efficiency. A new tank with greater capacity will be much more energy efficient than an aged tank that is maxed out and full to the brim.

There are a number of different options when it comes to milk cooling. The two most common systems are:

  • Direct expansion
  • Ice bank

Either of these systems can be complemented with additional cooling e.g. plate cooler or ice builders. Direct expansion cooling has become the norm and is believed to be the most efficient way to cool milk. However, modern ice bank systems can be as efficient and economical. Larger condensing units and faster ice building are the two main reasons for this. Where there is an issue with power supply, an ice bank can be ideal.

How big does a bulk tank need to be?

Milk must be cooled to 4 degrees directly after milking – otherwise bacteria numbers (TBC) will rapidly rise, thereby rapidly reducing milk quality. When assessing what is needed for effective and fast cooling, the following need to be considered:

  • Power and space requirements
  • Grant specifications
  • Local gas availability
  • Washing system
  • Elimination of residues
  • Warning system for cooling failure
  • Number of cows
  • Plate cooler or a chiller unit

The Glanbia Ireland Milk Purchasing Policy states that a farmer should have enough storage capacity for 5 milkings at peak milk volume. Storm Emma last year highlighted just how key it is to have enough storage on farm.

When assessing the size required keep in mind your expansion plans over the next 5-10 years and not just today’s volumes.

Cooling Capacity

We often see situations where milk cooling is the issue rather than storage capacity and the tank can not cope with cooling the volume of milk directly after milking. This leads to substandard milk quality and high TBCs. A plate cooler can be a great option for anyone in this scenario to effectively take some of the work away from the bulk tank, save energy and avoid issues with TBC. High temperature milk cannot be accepted into a processing plant.

Gas type and cost

In the early 1990’s refrigerant gases were identified as one of the major causes of the depletion of the ozone layer and hence the phase out of some of the older type gases, namely R12 and R22.

However, the main replacement gas R404A is now banned on any new installations from January 2020 onwards. Other gases are becoming available. The price of all refrigeration gases has dramatically increased since 2016. In particular, R404A has gone up over 1000% since January 2017.

Grant Aid

TAMS grant aid is currently available for milk cooling equipment. The base rate is 40% and some applicants e.g. partnerships, can get up to 60% back through TAMS.

Equipment eligible for TAMS grant aid includes:

  • Water heaters
  • Bulk milk tanks
  • Replacement compressor
  • Milk silos
  • Ice-builder
  • Plate cooler

Monitor systems

LASTLY, DON’T FORGET TO TURN IT ON! This is usually the most frequent cause of very high TBC (>1,000,000 cfu/ml). This happens all too often when other people are milking or when it is extremely busy on-farm e.g. silage season.

You can now retrofit a monitor for very low cost to help avoid disaster striking. A monitoring system will send automated text alerts to your phone quickly and ensure milk can be saved.

Problems

Contact a member of the Milk Quality team to get milk checked if the tank hasn’t been turned on. Don’t take a chance on it as your milk can make an entire tanker of milk unsuitable for processing. This can lead to costs of downgraded milk being passed back to the supplier identified as the root cause, and / or poor grades at month end. Don’t put ‘good’ morning milk in on top of milk that has been stored uncooled overnight.

Bulk tank checklist

  • Invest in a tank monitoring system to ensure it is never accidently turned off and is working correctly.
  • Check the bulk tank is turned on after each and every milking – make it a habit every time you pass the dairy.
  • An annual bulk tank service ensures that your tank is working correctly and efficiently.
  • Look for visible ‘butter lumps’ forming on the surface of the milk? This is generally a sign that agitation or cooling capacity is not correct.

Please find below the relevant contact details for your Milk Quality Manager:

Milk Quality Manager Area Phone Number
Jerry Cronin West Waterford / Castlelyons 087 246 8065
Pat Coady East Waterford / South Kilkenny 087 267 1082
Joe Kehoe Wexford / East Wicklow 087 265 9728
William O’Toole South Kilkenny / South Tipperary / Goresbridge 086 027 7230
John Fitzpatrick North Kilkenny / Donaghmore / Laois 086 042 6567
John Joe Collier Carlow / Kildare / Ballitore / Drogheda 087 256 4618
Sean Smith Virginia / Drogheda 087 288 8640
Fionnuala Malone 086 813 0726

First Published May 29 2018

Tagged with: Dairy

Processing